Messages - macVato

#1
Kodak Systems / Re: Harmony Issues and Recommendations
February 07, 2018, 03:38:07 PM
So for fine tuning I should edit the target curve, not the calibration curve.

Thank you.
#2
Kodak Systems / Harmony Issues and Recommendations
February 07, 2018, 02:24:58 PM
Hola,

First time poster, but been visiting this site for a bit, thank you for this.

1st question. When editing the calibration curve moving the node up does it lighten the screen value? as in moving the cyan value at 50 node (reading a 52 on press sheet) and inputting the node value 66 to 67. is that correct? or am i going the wrong way?

2nd question. After making the change nothing happens, is this a bug I read under this Topic: Plate Curves with Harmony in Prinergy? And does restarting Prinergy fix this, or will I have to redo the curve as Joe said he did.

3rd question. We recently switched to Fugi Superia Econmaxx-T plates (process-less), and they sent a tech in to get the plate up and going, he did put in a plate curve but no paper curve. when calibrating the paper curve should I still be using his plate curve?

We are using a X-Rite 500 Series Spectrodensitometer for CMYK values off the press sheet with no tint swatch and yes I work in a shop that values cheapness over getting things done correctly.